Code/Resource
Windows Develop
Linux-Unix program
Internet-Socket-Network
Web Server
Browser Client
Ftp Server
Ftp Client
Browser Plugins
Proxy Server
Email Server
Email Client
WEB Mail
Firewall-Security
Telnet Server
Telnet Client
ICQ-IM-Chat
Search Engine
Sniffer Package capture
Remote Control
xml-soap-webservice
P2P
WEB(ASP,PHP,...)
TCP/IP Stack
SNMP
Grid Computing
SilverLight
DNS
Cluster Service
Network Security
Communication-Mobile
Game Program
Editor
Multimedia program
Graph program
Compiler program
Compress-Decompress algrithms
Crypt_Decrypt algrithms
Mathimatics-Numerical algorithms
MultiLanguage
Disk/Storage
Java Develop
assembly language
Applications
Other systems
Database system
Embeded-SCM Develop
FlashMX/Flex
source in ebook
Delphi VCL
OS Develop
MiddleWare
MPI
MacOS develop
LabView
ELanguage
Software/Tools
E-Books
Artical/Document
RFC1381-MIB
Package: AdventNetSNMPAPI_4.zip [view]
Upload User: aonuowh
Upload Date: 2021-05-23
Package Size: 35390k
Code Size: 43k
Category:
SNMP
Development Platform:
C/C++
- -- Changes to rfc1381 (X.25 LAPB MIB):
- -- No changes needed.
- -- dperkins@scruznet.com
- RFC1381-MIB DEFINITIONS ::= BEGIN
- IMPORTS
- Counter
- FROM RFC1155-SMI
- transmission
- FROM RFC1213-MIB
- OBJECT-TYPE
- FROM RFC-1212;
- -- LAPB MIB
- lapb OBJECT IDENTIFIER ::= { transmission 16 }
- PositiveInteger ::= INTEGER (0..2147483647)
- IfIndexType ::= INTEGER (1..2147483647)
- -- IfIndexType specifies an index object for a table
- -- with entries that match entries in the MIB-II ifTable.
- -- The value of the index for the table will match the
- -- ifIndex entry for same interface in the ifTable.
- -- The values of this object range from 1 to ifNumber
- -- inclusive.
- -- ###########################################################
- -- LAPB Admn Table
- -- ###########################################################
- -- Support of the lapbAdmnTable is mandatory for all
- -- agents of systems that implement LAPB.
- lapbAdmnTable OBJECT-TYPE
- SYNTAX SEQUENCE OF LapbAdmnEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains objects that can be
- changed to manage a LAPB interface.
- Changing one of these parameters may take
- effect in the operating LAPB immediately or
- may wait until the interface is restarted
- depending on the details of the
- implementation.
- Most of the objects in this read-write table
- have corresponding read-only objects in the
- lapbOperTable that return the current
- operating value.
- The operating values may be different from
- these configured values if changed by XID
- negotiation or if a configured parameter was
- changed after the interface was started."
- ::= { lapb 1 }
- lapbAdmnEntry OBJECT-TYPE
- SYNTAX LapbAdmnEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Configured parameter values for a specific
- LAPB."
- INDEX { lapbAdmnIndex }
- ::= { lapbAdmnTable 1 }
- LapbAdmnEntry ::= SEQUENCE {
- lapbAdmnIndex
- IfIndexType,
- lapbAdmnStationType
- INTEGER,
- lapbAdmnControlField
- INTEGER,
- lapbAdmnTransmitN1FrameSize
- PositiveInteger,
- lapbAdmnReceiveN1FrameSize
- PositiveInteger,
- lapbAdmnTransmitKWindowSize
- INTEGER,
- lapbAdmnReceiveKWindowSize
- INTEGER,
- lapbAdmnN2RxmitCount
- INTEGER,
- lapbAdmnT1AckTimer
- PositiveInteger,
- lapbAdmnT2AckDelayTimer
- PositiveInteger,
- lapbAdmnT3DisconnectTimer
- PositiveInteger,
- lapbAdmnT4IdleTimer
- PositiveInteger,
- lapbAdmnActionInitiate
- INTEGER,
- lapbAdmnActionRecvDM
- INTEGER
- }
- lapbAdmnIndex OBJECT-TYPE
- SYNTAX IfIndexType
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The ifIndex value for the LAPB interface."
- ::= { lapbAdmnEntry 1 }
- lapbAdmnStationType OBJECT-TYPE
- SYNTAX INTEGER {
- dte (1),
- dce (2),
- dxe (3)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Identifies the desired station type of this
- interface."
- REFERENCE "ISO 7776 section 3.1"
- DEFVAL { dte }
- ::= { lapbAdmnEntry 2 }
- lapbAdmnControlField OBJECT-TYPE
- SYNTAX INTEGER {
- modulo8 (1),
- modulo128 (2)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The desired size of the sequence numbers
- used to number frames."
- REFERENCE "ISO 8885 Table 3, Name: HDLC Option - 10"
- DEFVAL { modulo8 }
- ::= { lapbAdmnEntry 3 }
- lapbAdmnTransmitN1FrameSize OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default maximum N1 frame size desired
- in number of bits for a frame transmitted by
- this DTE. This excludes flags and 0 bits
- inserted for transparency."
- REFERENCE "ISO 8885 Table 3,
- Name: Information Field length"
- DEFVAL { 36000 } -- 4500 * 8; 802.5 Frame size
- ::= { lapbAdmnEntry 4 }
- lapbAdmnReceiveN1FrameSize OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default maximum N1 frame size desired
- in number of bits for a frame the DCE/remote
- DTE transmits to this DTE. This excludes
- flags and 0 bits inserted for transparency."
- DEFVAL { 36000 } -- 4500 * 8; 802.5 Frame size
- ::= { lapbAdmnEntry 5 }
- lapbAdmnTransmitKWindowSize OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default transmit window size for this
- Interface. This is the maximum number of
- unacknowledged sequenced PDUs that may be
- outstanding from this DTE at any one time."
- REFERENCE "ISO 8885 Table 3, Name: Window size"
- DEFVAL { 7 }
- ::= { lapbAdmnEntry 6 }
- lapbAdmnReceiveKWindowSize OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default receive window size for this
- Interface. This is the maximum number of
- unacknowledged sequenced PDUs that may be
- outstanding from the DCE/remote DTE at any
- one time."
- REFERENCE "ISO 8885 Table 3, Name: Window size"
- DEFVAL { 7 }
- ::= { lapbAdmnEntry 7 }
- lapbAdmnN2RxmitCount OBJECT-TYPE
- SYNTAX INTEGER (0..65535)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default N2 retry counter for this
- interface. This specifies the number of
- times a PDU will be resent after the T1
- timer expires without an acknowledgement for
- the PDU."
- REFERENCE "ISO 8885 Table 3,
- Name: Retransmission Attempts"
- DEFVAL { 20 }
- ::= { lapbAdmnEntry 8 }
- lapbAdmnT1AckTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default T1 timer for this interface.
- This specifies the maximum time in
- Milliseconds to wait for acknowledgment of a
- PDU."
- REFERENCE "ISO 8885 Table 3, Name:
- Acknowledgement timer"
- DEFVAL { 3000 }
- ::= { lapbAdmnEntry 9 }
- lapbAdmnT2AckDelayTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The default T2 timer for this interface.
- This specifies the maximum time in
- Milliseconds to wait before sending an
- acknowledgment for a sequenced PDU. A value
- of zero means there will be no delay in
- acknowledgement generation."
- REFERENCE "ISO 8885 Table 3,
- Name: Reply delay timer"
- DEFVAL { 0 }
- ::= { lapbAdmnEntry 10 }
- lapbAdmnT3DisconnectTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The T3 timer for this interface. This
- specifies the time in Milliseconds to wait
- before considering the link disconnected. A
- value of zero indicates the link will be
- considered disconnected upon completion of
- the frame exchange to disconnect the link."
- REFERENCE "ISO 7776 section 5.7.1.3"
- DEFVAL { 60000 }
- ::= { lapbAdmnEntry 11 }
- lapbAdmnT4IdleTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The T4 timer for this interface. This
- specifies the maximum time in Milliseconds
- to allow without frames being exchanged on
- the data link. A value of 2147483647
- indicates no idle timer is being kept."
- REFERENCE "ISO 7776 section 5.7.1.4"
- DEFVAL { 2147483647 }
- ::= { lapbAdmnEntry 12 }
- lapbAdmnActionInitiate OBJECT-TYPE
- SYNTAX INTEGER {
- sendSABM (1),
- sendDISC (2),
- sendDM (3),
- none (4),
- other (5)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This identifies the action LAPB will take
- to initiate link set-up."
- DEFVAL { sendSABM }
- ::= { lapbAdmnEntry 13 }
- lapbAdmnActionRecvDM OBJECT-TYPE
- SYNTAX INTEGER {
- sendSABM (1),
- sendDISC (2),
- other (3)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This identifies the action LAPB will take
- when it receives a DM response."
- DEFVAL { sendSABM }
- ::= { lapbAdmnEntry 14 }
- -- ###########################################################
- -- LAPB operating parameters.
- -- ###########################################################
- -- Support of the lapbOperTable is mandatory for all
- -- agents of systems that implement LAPB.
- lapbOperTable OBJECT-TYPE
- SYNTAX SEQUENCE OF LapbOperEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains configuration
- information about interface parameters
- currently set in the interface. Many of
- these objects have corresponding objects in
- the lapbAdmnTable."
- ::= { lapb 2 }
- lapbOperEntry OBJECT-TYPE
- SYNTAX LapbOperEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Currently set parameter values for a
- specific LAPB."
- INDEX { lapbOperIndex }
- ::= { lapbOperTable 1 }
- LapbOperEntry ::= SEQUENCE {
- lapbOperIndex
- IfIndexType,
- lapbOperStationType
- INTEGER,
- lapbOperControlField
- INTEGER,
- lapbOperTransmitN1FrameSize
- PositiveInteger,
- lapbOperReceiveN1FrameSize
- PositiveInteger,
- lapbOperTransmitKWindowSize
- INTEGER,
- lapbOperReceiveKWindowSize
- INTEGER,
- lapbOperN2RxmitCount
- INTEGER,
- lapbOperT1AckTimer
- PositiveInteger,
- lapbOperT2AckDelayTimer
- PositiveInteger,
- lapbOperT3DisconnectTimer
- PositiveInteger,
- lapbOperT4IdleTimer
- PositiveInteger,
- lapbOperPortId
- OBJECT IDENTIFIER,
- lapbOperProtocolVersionId
- OBJECT IDENTIFIER
- }
- lapbOperIndex OBJECT-TYPE
- SYNTAX IfIndexType
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The ifIndex value for the LAPB interface."
- ::= { lapbOperEntry 1 }
- lapbOperStationType OBJECT-TYPE
- SYNTAX INTEGER {
- dte (1),
- dce (2),
- dxe (3)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Identifies the current operating station
- type of this interface. A value of dxe (3)
- indicates XID negotiation has not yet taken
- place."
- REFERENCE "ISO 7776 section 3.1"
- ::= { lapbOperEntry 2 }
- lapbOperControlField OBJECT-TYPE
- SYNTAX INTEGER {
- modulo8 (1),
- modulo128 (2)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current operating size of the sequence
- numbers used to number frames."
- REFERENCE "ISO 7776 section 3.3"
- ::= { lapbOperEntry 3 }
- lapbOperTransmitN1FrameSize OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current operating N1 frame size used
- for the maximum number of bits in a frame
- this DTE can transmit. This excludes flags
- and 0 bits inserted for transparency."
- REFERENCE "ISO 7776 section 5.7.3"
- ::= { lapbOperEntry 4 }
- lapbOperReceiveN1FrameSize OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-only
- STATUS mandatory
- -- See lapbOperTransmitN1FrameSize above
- DESCRIPTION
- "The current operating N1 frame size used
- for the maximum number of bits in a frame
- the DCE/remote DTE can transmit. This
- excludes flags and 0 bits inserted for
- transparency."
- ::= { lapbOperEntry 5 }
- lapbOperTransmitKWindowSize OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current PDU window size this Interface
- uses to transmit. This is the maximum
- number of unacknowledged sequenced PDUs that
- may be outstanding from this DTE at any one
- time."
- REFERENCE "ISO 7776 section 5.7.4"
- ::= { lapbOperEntry 6 }
- lapbOperReceiveKWindowSize OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current receive PDU window size for
- this Interface. This is the maximum number
- of unacknowledged sequenced PDUs that may be
- outstanding from the DCE/remote DTE at any
- one time."
- REFERENCE "ISO 7776 section 5.7.4"
- ::= { lapbOperEntry 7 }
- lapbOperN2RxmitCount OBJECT-TYPE
- SYNTAX INTEGER (0..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current N2 retry counter used for this
- interface. This specifies the number of
- times a PDU will be resent after the T1
- timer expires without an acknowledgement for
- the PDU."
- REFERENCE "ISO 7776 section 5.7.2"
- ::= { lapbOperEntry 8 }
- lapbOperT1AckTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current T1 timer for this interface.
- This specifies the maximum time in
- Milliseconds to wait for acknowledgment of a
- PDU."
- REFERENCE "ISO 7776 section 5.7.1.1"
- ::= { lapbOperEntry 9 }
- lapbOperT2AckDelayTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current T2 timer for this interface.
- This specifies the maximum time in
- Milliseconds to wait before sending an
- acknowledgment for a sequenced PDU. A value
- of zero means there will be no delay in
- acknowledgement generation."
- REFERENCE "ISO 7776 section 5.7.1.2"
- ::= { lapbOperEntry 10 }
- lapbOperT3DisconnectTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current T3 timer for this interface.
- This specifies the time in Milliseconds to
- wait before considering the link
- disconnected. A value of zero indicates the
- link will be considered disconnected upon
- completion of the frame exchange to
- disconnect the link."
- REFERENCE "ISO 7776 section 5.7.1.3"
- ::= { lapbOperEntry 11 }
- lapbOperT4IdleTimer OBJECT-TYPE
- SYNTAX PositiveInteger
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The current T4 timer for this interface.
- This specifies the maximum time in
- Milliseconds to allow without frames being
- exchanged on the data link. A value of
- 2147483647 indicates no idle timer is being
- kept."
- REFERENCE "ISO 7776 section 5.7.1.4"
- ::= { lapbOperEntry 12 }
- lapbOperPortId OBJECT-TYPE
- SYNTAX OBJECT IDENTIFIER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This object identifies an instance of the
- index object in the first group of objects
- in the MIB specific to the physical device
- or interface used to send and receive
- frames. If an agent does not support any
- such objects, it should return nullSpec
- OBJECT IDENTIFIER {0 0}."
- ::= { lapbOperEntry 13 }
- lapbOperProtocolVersionId OBJECT-TYPE
- SYNTAX OBJECT IDENTIFIER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This object identifies the version of the
- lapb protocol implemented by this
- interface."
- ::= { lapbOperEntry 14 }
- -- ###########################################################
- -- LAPB Flow Table
- -- ###########################################################
- -- Support of the lapbFlowTable is mandatory for all
- -- agents of systems that implement LAPB.
- lapbFlowTable OBJECT-TYPE
- SYNTAX SEQUENCE OF LapbFlowEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table defines the objects recorded by
- LAPB to provide information about the
- traffic flow through the interface."
- ::= { lapb 3 }
- lapbFlowEntry OBJECT-TYPE
- SYNTAX LapbFlowEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The information regarding the effects of
- flow controls in LAPB."
- INDEX { lapbFlowIfIndex }
- ::= { lapbFlowTable 1 }
- LapbFlowEntry ::= SEQUENCE {
- lapbFlowIfIndex
- IfIndexType,
- lapbFlowStateChanges
- Counter,
- lapbFlowChangeReason
- INTEGER,
- lapbFlowCurrentMode
- INTEGER,
- lapbFlowBusyDefers
- Counter,
- lapbFlowRejOutPkts
- Counter,
- lapbFlowRejInPkts
- Counter,
- lapbFlowT1Timeouts
- Counter,
- lapbFlowFrmrSent
- OCTET STRING,
- lapbFlowFrmrReceived
- OCTET STRING,
- lapbFlowXidReceived
- OCTET STRING
- }
- lapbFlowIfIndex OBJECT-TYPE
- SYNTAX IfIndexType
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The ifIndex value for the LAPB Interface."
- ::= { lapbFlowEntry 1 }
- lapbFlowStateChanges OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of LAPB State Changes, including
- resets."
- ::= { lapbFlowEntry 2 }
- lapbFlowChangeReason OBJECT-TYPE
- SYNTAX INTEGER {
- notStarted (1), -- Initial state
- abmEntered (2), -- SABM or UA
- abmeEntered (3), -- SABME or UA
- abmReset (4), -- SABM in ABM
- abmeReset (5), -- SABME in ABME
- dmReceived (6), -- DM Response
- dmSent (7), -- DM sent
- discReceived (8), -- DISC Response
- discSent (9), -- DISC Sent
- frmrReceived (10), -- FRMR Received
- frmrSent (11), -- FRMR Sent
- n2Timeout (12), -- N2 Timer Expired
- other (13)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The reason for the most recent incrementing
- of lapbFlowStateChanges. A DM or DISC frame
- generated to initiate link set-up does not
- alter this object. When the MIB-II object
- ifOperStatus does not have a value of
- testing, there exists a correlation between
- this object and ifOperStatus. IfOperStatus
- will have a value of up when this object
- contains: abmEntered, abmeEntered,
- abmReset, or abmeReset. IfOperStatus will
- have a value of down when this object has a
- value of notStarted, or dmReceived through
- n2Timeout. There is no correlation when
- this object has the value other."
- ::= { lapbFlowEntry 3 }
- lapbFlowCurrentMode OBJECT-TYPE
- SYNTAX INTEGER {
- disconnected (1),
- -- initial state or DISC received
- linkSetup (2),
- -- SABM sent
- frameReject (3),
- -- Invalid frame received and
- -- FRMR sent
- disconnectRequest (4),
- -- DISC sent
- informationTransfer (5),
- -- normal information transfer state
- -- SABM(E) sent and UA received, or
- -- SABM(E) received and UA sent
- rejFrameSent (6),
- -- invalid NS received and REJ sent
- waitingAcknowledgement (7),
- -- T1 expired and RR sent
- stationBusy (8),
- -- RNR sent
- remoteStationBusy (9),
- -- RNR received
- bothStationsBusy (10),
- -- RNR received and RNR sent
- waitingAckStationBusy (11),
- -- T1 expired, RNR sent
- waitingAckRemoteBusy (12),
- -- T1 expired, RNR received
- waitingAckBothBusy (13),
- -- T1 expired, RNR sent,
- -- and RNR received
- rejFrameSentRemoteBusy (14),
- -- REJ sent and RNR received
- xidFrameSent (15),
- -- XID frame sent
- error (16),
- -- An error state other than
- -- a one defined above
- other (17)
- -- A state not listed above
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The current condition of the conversation."
- ::= { lapbFlowEntry 4 }
- lapbFlowBusyDefers OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of times this device was unable
- to transmit a frame due to a perceived
- remote busy condition. Busy conditions can
- result from the receipt of an RNR from the
- remote device, the lack of valid sequence
- number space (window saturation), or other
- conditions."
- ::= { lapbFlowEntry 5 }
- lapbFlowRejOutPkts OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of REJ or SREJ frames sent by
- this station."
- ::= { lapbFlowEntry 6 }
- lapbFlowRejInPkts OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of REJ or SREJ frames received
- by this station."
- ::= { lapbFlowEntry 7 }
- lapbFlowT1Timeouts OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of times a re-transmission was
- effected by the T1 Timer expiring."
- ::= { lapbFlowEntry 8 }
- lapbFlowFrmrSent OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..7))
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The Information Field of the FRMR most
- recently sent. If no FRMR has been sent
- (the normal case) or the information isn't
- available, this will be an OCTET STRING of
- zero length."
- REFERENCE "ISO 7776 Section 4.3.9, tables 7 and 8"
- ::= { lapbFlowEntry 9 }
- lapbFlowFrmrReceived OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..7))
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The Information Field of the FRMR most
- recently received. If no FRMR has been
- received (the normal case) or the
- information isn't available, this will be an
- OCTET STRING of zero length."
- REFERENCE "ISO 7776 Section 4.3.9, tables 7 and 8"
- ::= { lapbFlowEntry 10 }
- lapbFlowXidReceived OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..8206))
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The Information Field of the XID frame most
- recently received. If no XID frame has been
- received, this will be an OCTET STRING of
- zero length."
- REFERENCE "ISO 8885"
- ::= { lapbFlowEntry 11 }
- -- ###########################################################
- -- LAPB XID Table
- -- ###########################################################
- -- Support for the lapbXidTable is mandatory for all agents
- -- of systems that have a LAPB implementation using XID
- -- negotiation. Agents of systems without XID negotiation
- -- support should not implement this table.
- lapbXidTable OBJECT-TYPE
- SYNTAX SEQUENCE OF LapbXidEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table defines values to use for XID
- negotiation that are not found in the
- lapbAdmnTable. This table is optional for
- implementations that don't support XID and
- mandatory for implementations that do
- initiate XID negotiation."
- ::= { lapb 4 }
- lapbXidEntry OBJECT-TYPE
- SYNTAX LapbXidEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "XId negotiation parameter values for a
- specific LAPB."
- INDEX { lapbXidIndex }
- ::= { lapbXidTable 1 }
- LapbXidEntry ::= SEQUENCE {
- lapbXidIndex
- IfIndexType,
- lapbXidAdRIdentifier
- OCTET STRING,
- lapbXidAdRAddress
- OCTET STRING,
- lapbXidParameterUniqueIdentifier
- OCTET STRING,
- lapbXidGroupAddress
- OCTET STRING,
- lapbXidPortNumber
- OCTET STRING,
- lapbXidUserDataSubfield
- OCTET STRING
- }
- lapbXidIndex OBJECT-TYPE
- SYNTAX IfIndexType
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The ifIndex value for the LAPB interface."
- ::= { lapbXidEntry 1 }
- lapbXidAdRIdentifier OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..255))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value of the Address Resolution
- Identifier. A zero length string indicates
- no Identifier value has been assigned."
- REFERENCE "ISO 8885 Table 2, Name: Identifier"
- DEFVAL { ''h }
- ::= { lapbXidEntry 2 }
- lapbXidAdRAddress OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..255))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value of the Address Resolution
- Address. A zero length string indicates no
- Address value has been assigned."
- REFERENCE "ISO 8885 Table 2, Name: Address"
- DEFVAL { ''h }
- ::= { lapbXidEntry 3 }
- lapbXidParameterUniqueIdentifier OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..255))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value of the parameter unique
- Identifier. A zero length string indicates
- no Unique identifier value has been
- assigned."
- REFERENCE "ISO 8885 Table 3, Name: Identifier"
- DEFVAL { ''h }
- ::= { lapbXidEntry 4 }
- lapbXidGroupAddress OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..255))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The value of the parameter Group address.
- A zero length string indicates no Group
- address value has been assigned."
- REFERENCE "ISO 8885 Table 3, Name: Group address"
- DEFVAL { ''h }
- ::= { lapbXidEntry 5 }
- lapbXidPortNumber OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..255))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The port number assigned for this link. A
- zero length string indicates no local port
- number identifier has been assigned."
- REFERENCE "ISO 8885 Table 3, Name: Port number"
- DEFVAL { ''h }
- ::= { lapbXidEntry 6 }
- lapbXidUserDataSubfield OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..8206))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "A user data subfield, if any, to be
- transmitted in an XID frame. A zero length
- frame indicates no user data subfield has
- been assigned. The octet string should
- include both the User data identifier and
- User data field as shown in Figures 1 and
- 4."
- REFERENCE "ISO 8885 section 4.3"
- DEFVAL { ''h }
- ::= { lapbXidEntry 7 }
- -- ###########################################################
- -- LAPB protocol versions
- -- ###########################################################
- lapbProtocolVersion OBJECT IDENTIFIER
- ::= { lapb 5 }
- lapbProtocolIso7776v1986 OBJECT IDENTIFIER
- ::= { lapbProtocolVersion 1 }
- lapbProtocolCcittV1980 OBJECT IDENTIFIER
- ::= { lapbProtocolVersion 2 }
- lapbProtocolCcittV1984 OBJECT IDENTIFIER
- ::= { lapbProtocolVersion 3 }
- -- The following describes some of the MIB-II interface
- -- objects and their relationship with the objects in this
- -- MIB extension.
- -- ifDescr: describes the interface. It should include
- -- identification information for the physical line and a
- -- description of the network. For connections to PDNs,
- -- it should name the PDN.
- -- ifMtu: the maximum number of octets an upper layer can
- -- pass to this interface as a single frame.
- -- ifSpeed:
- -- ifAdminStatus:
- -- ifOperStatus:
- -- ifLastChange: the last time the state of the interface
- -- changed. A reset is considered an instantaneous change to
- -- the ndm state and back to abm or abme. This will be the
- -- last time that lapbFlowChangeReason and lapbFlowChanges
- -- changed.
- -- ifInOctets: contains the number of octets
- -- received from the peer LAPB including FCS.
- -- ifInUcastPkts: contains the number of I-frames delivered
- -- by this interface to a higher layer interface.
- -- ifInDiscards: contains the number of received
- -- frames discarded because of internal conditions
- -- (such as lack of buffering).
- -- ifInErrors: contains the number of Invalid frames received.
- -- This does not have any relationship with the number REJ,
- -- or RNR frames sent or received.
- -- ifInUnknownProtos: contains the number of frames
- -- that were correct but were dropped because they
- -- were inappropriate for the current state. This
- -- includes an invalid Poll bit, an unknown address,
- -- or other condition such as an RNR when connection
- -- not established. This also includes the number of
- -- DISC or other frames that were ignored because the
- -- link was not established and this interface was not
- -- configured to perform link setup on that type frame.
- -- ifOutOctets: number of octets sent to peer including
- -- FCS octets.
- -- ifOutUcastPkts: number of I-frames received from
- -- a higher layer for transmission to peer.
- -- ifOutDiscards: number of frames to be sent that were
- -- dropped due to internal conditions such as buffering etc.
- -- ifOutErrors: number of transmissions that failed
- -- due to errors or were considered invalid by the receiver.
- -- This does not have any relationship with the number REJ,
- -- or RNR frames sent or received.
- -- ifOutQLen: number of frames waiting to be transmitted.
- -- This MIB does not provide any support for:
- -- Multilink procedure (MLP) in ISO 7776 section 6
- -- LLC Pbit timer
- -- LLC REJ timer
- -- LLC Busy State Timer 7.8.1.4
- -- ###########################################################
- END